the
chaoyany tank machine control panel (三)
The product
is our factory especial to design new type controller, when
the make the cold,the posting temperature high the room temperature,the
pump not working, the plant unit wind machine running as normal,
when the room temperature high than the positing temperature,the
pump working. When make heat in winter, the positing temperature
low than the room temperature, the warmer not work,the machine
group work as usually,when the temperature low than the posting
time,the warmer power on to work.
|
|
|
|
1wind direction press
the key the wind direction is transversely sweep or dot sweep.
2.running/stop press the key could running or close the air-conditioning
machinery.
3.the temperature add key the key could add the temperature.
4.the temperature reduce key press the key could reduce the
temperature.
5.the distant control receive windows the receive windows
could use receive the distant control sign.
6.running the lamp bright ,the machine is starting work.
7.the wind direction show when the lamp bright show the wind
direction is transversely sweep.
8.the time display the display show the posting time or the
close machine time.
9.positing time the lamp bright show the time display show
the positing open machine or close machine time.
10.the rest time the lamp bright,the time display show the
rest time and when close time the open machine time.
11.the wind speed pointer.it is the sports display,the wind
machine high speed ,the lamp is flash quickly.
|
12.the room
temperature 。The lamp bright show the room temperature.
13positing temperature 。The lamp temperature show the positing
temperature.
14.the temperature display. 。The display could show the positing
temperature.
15.make cold the lamp bright show the machine is in the make
cold station ,the pump is working.
16make heat the lamp bright show the machine is in the make
heat station, the warmer is in working.
17.the setting time reduce key press the key could reduce
the machine positing the open time and close time.
18.the setting time add key press the key could add the machine
positing open time and close time.
19.function: : press the key could change the machine work
station:make cold or make heat
21.the wind speed press the key could recursion choice the
wind speed :high,middle,low.
Note:the machine have the single cold type and the pair type
two model.
|
|
|
| |
|
the setting one
drag two water temperature air conditioner type proceedings:
1.When one drag two water temperature
air conditioner ,must know the up and two conditioner use
the electric power supply must is the same phase. It must
use the three pole battery socket.
2. Not use the two feet plug drag line board,and the the three
eye socket. Use the one drag two conditioner.
3. When the pump line, must use the electric pen to test the
up and down air conditioner pump to outlet, the fire line
must to the fire line ,the null line to the null line. 。
4.If by the above require to operation ,the conditioner pass
the electric wire, but when in the close station, the pump
is running usually, must change the one of the power socket
to the outline of the conditioner. And then by the three require
to operation that to arrive the single operation
5. Because when the normal electric workman fitting the plug
,not by the international standards to line the wire, the
left null line and the right line is fire to the ground principle,when
the conditioner is in shut, it is shut the one wire, it could
show the four item , for our fitting the one drag two air
conditioner. Not line the red line to the red line of the
outlet to the conditioner. The black line to the black line
to the pump,if the short circuit,it could break the controller,
it must use the electric pen.the fire line to the fire line,the
null to the null line.
|
|
the set using attendance
and servicing
1. And machine
water outlet connect must use the copper tube connect tube
use the combating ageing high pressure rubber connect tube,it
could lest fitting break connecter.
2.Machine condensing pipe could not show press squash, knee
bend and the water road not pass appearance。
3. Machine using temperature of the water not low than 7℃,
the heat water not high than 80℃,the temperature above 5℃。
4. It must protection the verge of the wind and the tube of
enter water compact and humectancy ,and prevent the pow to
cost.
5. The enter water tube, it prompting is quasi, not make wrong,
normal the left is enter tube, right is enter water tube,
the enter method left ,right,back three practice choice.
6. The conditioner using voltage is 220V±10%, the frequency
is 50Hz, the could fastness connect to the ground.
7. Three oculi outlet must the left is the null the right
is fire to the ground, prevent the induction to electric.
8.The fitting pump must short than 10 centimeter, the pump
body is low than the gassing enter water.。
9.The plant unit must near the water well, the pump waterinlet
pipe must add the filtration equipment, to prevent the grit
enter the pump to cause the pump break.。
10. The onhook fitting the board must use the level of transverse,
the longitudinal vertical, not the condensed water to the
group ,the board not endure the strength to 50kg .
11. The plant unit line is computer control not than the option
change, it could keep the clean to the board.。
12.The filter to the air must to periodical to cleaning. It
must clean very demilune one time by the using. To pressure
the enter the wind and change cold effictiveness.
the special use declaration:
If
you not need the conditioner running, also need the water
to using, and the conditioner plush power source. Press the
control key ,the computer could control pump,the pump could
work independency, or press the tank function key, the same
could arrive the function, the temperature of the computer
that the digit tube show the "PU"mode computer ,all the lamp
flash .
|
|
the question in using:
1.In the make
cold mode , if the conditioner not running, must reduce the
positing temperature, the room temperature in the summer 33℃,
the positing temperature must choice the 28℃,when the room
temperature arrive 28℃,the machine could stop to working.
Temperature undermost to the 15℃.
2.When in the make heat mode ,the conditioner not running,
if add the positing temperature, the positing temperature
could high than the room temperature to running.the temperature
max is the 35℃.。
3.When in the make heat mode to close the machine ,the conditioner
time delay running 2 minute could close the machine.。
4.If the conditioner have no power show, must to test the
outlet if have power on, the socket connecter if is good,
the computer control wire fuse whether is good . 。
5. If the conditioner not to make cold, must test the pump
fuse if is good ,If water outlet in the running, water leakage
6.The product use the computer controller ,have the pump product
equipment. When the pump have not working in long time and
have produce the dead appearance, the conditioner could warning
,must to shut down the power, and trouble clearing
7. Must let the water that in the tube cleaning in the winter,
to prevent the tube of the copper break, and let the pump
freeze-proof work
8.The tank type cool-warmer conditioner have the PTC heat
equipment, when the outlet gate not let any metal and any
conductor object to enter, to break the heat machine to bring
the electric shock danger and burn out equipment.
9. Before one decimeter the enter wind gate not place any
equipment ,to keep the enter wind .
10. Not to dismantling by self in the using, not change the
line ,could kindly to let the have qualification professional
to test and maintenance or let the distribution and sales
connect with our factory technique department.。
11.The concrete
using please by the prompting function operation.
|
 |
|
|
| |
|
|